All 5 Aqara water leak sensors offline (no Zigbee routers in the mesh) #225

Open
opened 2026-09-15 17:09:57 +00:00 by claude-bot · 1 comment
Collaborator

Noticed 2026-09-15 while surveying entities for the dashboard redesign.

These ZHA (ConBee II) water leak sensors are unavailable, with no battery reading:

  • Basement Bathroom (binary_sensor.lumi_lumi_sensor_wleak_aq1_5b795408_ias_zone)
  • Furnace (binary_sensor.lumi_lumi_sensor_wleak_aq1_93296508_ias_zone)
  • Laundry Sink (binary_sensor.lumi_lumi_sensor_wleak_aq1_cec95408_ias_zone)
  • Water Tank (binary_sensor.lumi_lumi_sensor_wleak_aq1_ias_zone)

Only Kitchen Sink is alive (battery 84%). Likely dead CR2032 batteries or Zigbee mesh dropout.

These are safety devices � a leak would currently go undetected in 4 locations. Suggested: replace batteries, re-pair any that do not come back, and consider an automation that notifies when a leak sensor goes unavailable. The new Security dashboard view surfaces all 5 so the failure is at least visible now.

Noticed 2026-09-15 while surveying entities for the dashboard redesign. These ZHA (ConBee II) water leak sensors are `unavailable`, with no battery reading: - Basement Bathroom (`binary_sensor.lumi_lumi_sensor_wleak_aq1_5b795408_ias_zone`) - Furnace (`binary_sensor.lumi_lumi_sensor_wleak_aq1_93296508_ias_zone`) - Laundry Sink (`binary_sensor.lumi_lumi_sensor_wleak_aq1_cec95408_ias_zone`) - Water Tank (`binary_sensor.lumi_lumi_sensor_wleak_aq1_ias_zone`) Only **Kitchen Sink** is alive (battery 84%). Likely dead CR2032 batteries or Zigbee mesh dropout. These are safety devices � a leak would currently go undetected in 4 locations. Suggested: replace batteries, re-pair any that do not come back, and consider an automation that notifies when a leak sensor goes `unavailable`. The new Security dashboard view surfaces all 5 so the failure is at least visible now.
Author
Collaborator

Update 2026-10-26: all 5 are offline, and the mesh has no routers

This comes from ZHA's device table, pulled over the HA websocket (zha/devices) on HA 2026.10.4.

Network: a ConBee II coordinator (deCONZ radio) on Zigbee channel 15, plus 7 devices. Every device is a battery EndDevice. There are zero Zigbee routers. The TP-Link plugs, strips and lamps "on the path" are Wi‑Fi devices, and Wi‑Fi devices don't repeat Zigbee. So every sensor has to reach the ConBee directly, through floors and walls.

Device Area Available Last seen
Water Sensor - Water Tank utility_room ❌ 2026-09-14 10:38
Water Sensor - Furnace utility_room ❌ 2026-09-14 10:38
Water Sensor - Basement Bathroom basement ❌ 2026-09-14 10:54
Water Sensor - Laundry Sink laundry_room ❌ 2026-09-14 10:59
Water Sensor - Kitchen Sink kitchen ❌ 2026-10-08 17:56
Aqara Button - Office office ✅ today, LQI 255
Aqara Mini Button by door garage ✅ today, LQI 255

The four basement and utility sensors all dropped within 21 minutes of each other on 09-14. That looks like a network event, such as a coordinator or HA restart, that they never rejoined after. Four batteries dying at once is unlikely. Aqara end devices are known not to rejoin on their own after losing their parent. The two buttons that still work are the closest to the coordinator.

The leak automations (water_leak_furnace, _kitchen_sink, _laundry_sink, _hot_water_tank) are still on, so a leak right now would set off nothing, and nothing alerted that the sensors were gone for 6 weeks.

Plan

  1. Add Zigbee routers (mains-powered Zigbee devices) between the office and the basement. At minimum, put one in the utility room, which holds the water tank and furnace sensors, and one roughly halfway. Aqara end devices are picky about which routers they stay attached to, so choose routers that are known to work with Aqara:
    • Aqara's own mains devices (smart plug, relay), or an IKEA TRÅDFRI signal repeater or plug. These are the commonly reported safe choices.
    • Or a USB Zigbee stick flashed with router firmware, such as a CC2652P-based stick. These are USB-powered, so one can run from a phone charger or a spare USB port in the utility room.
    • Or a PoE Zigbee adapter in router mode, such as an SMLIGHT SLZB-06, powered from the Ubiquiti PoE port.
  2. The old Samsung SmartThings hub can't do this. It's a coordinator for its own Zigbee network, not a router that can join ZHA's. Retire it.
  3. Re-pair all 5 leak sensors after the routers are in place. In ZHA → Add device, hold each sensor's top button about 5 s until it blinks. Pair each one where it lives, so it attaches through the nearest router. If one won't pair, try a fresh CR2032 battery.
  4. Add an alert when any leak sensor is unavailable for 6 h or more, so this can't go silent again. This could be an HA automation that notifies, or a check through Hermes.
  5. Later, consider replacing the ConBee II (deCONZ firmware) with a current coordinator (SMLIGHT SLZB-06/07, Sonoff ZBDongle-E/-P, HA Connect ZBT). ZHA has a built-in radio migration that keeps the pairings. This is optional and not needed for the fix.

Channel 15 is OK: it sits between Wi‑Fi channels 1 and 6. If you rearrange the Wi‑Fi, keep 2.4 GHz on channel 1, 6 or 11.

🤖 Generated with Claude Code

## Update 2026-10-26: all 5 are offline, and the mesh has no routers This comes from ZHA's device table, pulled over the HA websocket (`zha/devices`) on HA 2026.10.4. **Network:** a ConBee II coordinator (deCONZ radio) on Zigbee **channel 15**, plus 7 devices. **Every device is a battery `EndDevice`. There are zero Zigbee routers.** The TP-Link plugs, strips and lamps "on the path" are Wi‑Fi devices, and Wi‑Fi devices don't repeat Zigbee. So every sensor has to reach the ConBee directly, through floors and walls. | Device | Area | Available | Last seen | |---|---|---|---| | Water Sensor - Water Tank | utility_room | ❌ | 2026-09-14 10:38 | | Water Sensor - Furnace | utility_room | ❌ | 2026-09-14 10:38 | | Water Sensor - Basement Bathroom | basement | ❌ | 2026-09-14 10:54 | | Water Sensor - Laundry Sink | laundry_room | ❌ | 2026-09-14 10:59 | | Water Sensor - Kitchen Sink | kitchen | ❌ | 2026-10-08 17:56 | | Aqara Button - Office | office | ✅ | today, LQI 255 | | Aqara Mini Button by door | garage | ✅ | today, LQI 255 | The four basement and utility sensors all dropped within 21 minutes of each other on 09-14. That looks like a network event, such as a coordinator or HA restart, that they never rejoined after. Four batteries dying at once is unlikely. Aqara end devices are known not to rejoin on their own after losing their parent. The two buttons that still work are the closest to the coordinator. The leak automations (`water_leak_furnace`, `_kitchen_sink`, `_laundry_sink`, `_hot_water_tank`) are still **on**, so a leak right now would set off nothing, and nothing alerted that the sensors were gone for 6 weeks. ## Plan 1. **Add Zigbee routers (mains-powered Zigbee devices) between the office and the basement.** At minimum, put one in the utility room, which holds the water tank and furnace sensors, and one roughly halfway. Aqara end devices are picky about which routers they stay attached to, so choose routers that are known to work with Aqara: - Aqara's own mains devices (smart plug, relay), or an IKEA TRÅDFRI signal repeater or plug. These are the commonly reported safe choices. - Or a USB Zigbee stick flashed with **router** firmware, such as a CC2652P-based stick. These are USB-powered, so one can run from a phone charger or a spare USB port in the utility room. - Or a PoE Zigbee adapter in router mode, such as an SMLIGHT SLZB-06, powered from the Ubiquiti PoE port. 2. **The old Samsung SmartThings hub can't do this.** It's a coordinator for its own Zigbee network, not a router that can join ZHA's. Retire it. 3. **Re-pair all 5 leak sensors after the routers are in place.** In ZHA → Add device, hold each sensor's top button about 5 s until it blinks. Pair each one **where it lives**, so it attaches through the nearest router. If one won't pair, try a fresh CR2032 battery. 4. **Add an alert** when any leak sensor is `unavailable` for 6 h or more, so this can't go silent again. This could be an HA automation that notifies, or a check through Hermes. 5. Later, consider replacing the ConBee II (deCONZ firmware) with a current coordinator (SMLIGHT SLZB-06/07, Sonoff ZBDongle-E/-P, HA Connect ZBT). ZHA has a built-in radio migration that keeps the pairings. This is optional and not needed for the fix. Channel 15 is OK: it sits between Wi‑Fi channels 1 and 6. If you rearrange the Wi‑Fi, keep 2.4 GHz on channel 1, 6 or 11. 🤖 Generated with [Claude Code](https://claude.com/claude-code)
claude-bot changed title from 4 of 5 Aqara water leak sensors unavailable in Home Assistant to All 5 Aqara water leak sensors offline (no Zigbee routers in the mesh) 2026-10-27 02:15:15 +00:00
Sign in to join this conversation.
No milestone
No project
No assignees
1 participant
Notifications
Due date
The due date is invalid or out of range. Please use the format "yyyy-mm-dd".

No due date set.

Dependencies

No dependencies set

Reference
matt/homelab-docker#225
No description provided.